Rapid Restroom
331601-002 12/09
REMINDER: Keep your dated proof of purchase for warranty purposes! Attach it to this manual or file it for safekeeping.
Description
READ AND FOLLOW ALL INSTRUCTIONS BEFORE
BEGINNING INSTALLATION
Safety Guidelines
This manual contains information that is very important
to know and understand. This information is provided for
SAFETY and to PREVENT EQUIPMENT PROBLEMS. To help
recognize this information, observe the following symbols.
Warning indicates a potentially
hazardous situation which, if not
avoided, could result in death or serious injury.
Caution indicates a potentially
hazardous situation which, if not
avoided, may result in minor or moderate injury.
Notice indicates important
information, that if not followed, may
cause damage to equipment.
NOTE: Information that requires special attention.
CALIFORNIA PROPOSITION 65
This product or its power cord may
contain chemicals known to the State
of California to cause cancer and birth defects or other
reproductive harm. Wash hands after handling.
• Besuretheoorislevelwithin1/8in.forthe
length and width of the tank
• Usesoapywatertolubricateallsealstoaid
installation
• Testunitbeforemountingtoilet.CheckOn/Off
levels of switch.
• Donotovertorquemountingscrews
• Refertoowner’smanualforpumpperformance
and operation.
• Ifabuilt-ininstallationistobeused,locatetank
in an area that will allow access to the pump
and switch.
• Forelectricalinformationrefertolocalcodes.
Thetoiletwillnotushunlessitisproperly
vented.
SAVE THESE INSTRUCTIONS
Installation Procedures
Unit Inspection
Inspect your unit very carefully before installing. Make
sure there are no punctures in the tank.
Unit Location
Once the unit has been inspected and cleared of any
transportation damage, select a location for installation
which is readily accessible to the existing discharge and
ventlines;aswellasaccesstoa120VACgrounded
3-prong receptacle.
Pump must be plugged into an
outlet receptacle that includes a
Ground Fault Circuit Interrupter (GFCI). In the event of
current leakage, a GFCI will trip, thus reducing the risk of
serious injury or death from electrical shock.
Unit Installation
Inspect your system carefully before
installation; make sure there are no punctures in the tank.
During assembly, make sure no
screws, nails or other sharp objects puncture the tank.
1. If a built in installation is to be done, locate the
system in an area that will allow access to the pump
and switch after installation.
2. Determinetheorientationofthetoiletonthetank,
after determining the orientation install the brass
closet bolts provided (Figures 1 and 2).
Installation Instructions EXJRPP
The Professional’s Line
Please read and save these instructions. Read carefully before attempting to assemble, install, oper-
ate or maintain the product described. Protect yourself and others by observing all safety information.
Failure to comply with instructions could result in personal injury and/or property damage! Retain
instructions for future reference.
© 2009 Blue Angel
Pumps For parts, product & service information
visit www.waynewatersystems.com
See Warranty on page 5 for important information about commercial use of this product
Figure 1: Toilet Position Figure 2: Toilet Position
Vista de página 0
1 2 3 4 5 6 ... 15 16

Resumo do Conteúdo

Página 1 - Rapid Restroom

Rapid Restroom331601-002 12/09REMINDER: Keep your dated proof of purchase for warranty purposes! Attach it to this manual or file it for safekeeping.D

Página 2 - (continued)

10 FrInstructions de MontageEXJRPPGARANTIE LIMITÉEPourunanàcompterdeladated’achat,BlueAngel(“BlueAngel”)vasréparerouremplacer,àsono

Página 3

11 SpRetrete Instantáneo331601-002 12/09RECORDATORIO: ¡Guarde su comprobante de compra con fecha para fines de la garantía!Adjúntela a este manual o a

Página 4 - Operating Instructions

12 SpInstrucciones para la InstalaciónEXJRPP2. Determinelaorientacióndelexcusadosobreeltanque;unavez determinada la orientación, instale lo

Página 5 - LIMITED WARRANTY

13 SpInstrucciones para la InstalaciónEXJRPPd. Sielsistemafuncionacorrectamente,continúeconlainstalación.7. Hagalasconexionesdenitivas

Página 6 - Toilette Rapide

14 SpInstrucciones para la InstalaciónEXJRPPTubería de 5,1 o 7,6 cm (2 o 3 in.)de ventilación (no se proporciona)TuberíadeDesagüe(no se proporcion

Página 7

15 SpInstrucciones para la InstalaciónEXJRPPGarantía LimitadaBlue Angel (”Blue Angel“) le ofrece una garantía de un año a partir de la fecha de compra

Página 8

16Operating InstructionsInstructions de MontageInstrucciones para la InstalaciónEXJRPPNotes/ Notas

Página 9 - Instructions de Montage

2Operating InstructionsEXJRPP3. Determinethelocationorlayoutofotherxturestobe used with your Rapid Restroom. Tubs, showers, and sinks will

Página 10 - GARANTIE LIMITÉE

d. If the system cycles properly, continue the installation.7. Make permanent connections between the discharge pipe and the house discharge pipe.8.

Página 11 - Retrete Instantáneo

4www.waynewatersystems.comOperating InstructionsEXJRPP2 or 3 in. Ventilation Pipe (Not Included)DischargePipe(NotIncluded)CheckValve2 in. seal2 or

Página 12 - (Continuación)

5www.waynewatersystems.comOperating InstructionsEXJRPPLIMITED WARRANTYFor one year from date of purchase, Blue Angel (”Blue Angel“) will repair or rep

Página 13

6 FrToilette Rapide331601-002 12/09MÉMENTO : Gardez votre preuve datée d’achat à fin de la garantie ! Joignez-la à ce manuel ou classez-la dans un dos

Página 14

7 FrInstructions de MontageEXJRPP2. Déterminerl’orientationdelatoilettesurleréservoir.Aprèsavoirdéterminél’orientation,installerlesbou

Página 15 - Garantía Limitada

8FrInstructions de MontageEXJRPP7. Établir des raccords permanents entre le tuyau de décharge et le drain résidentiel.8. Installerletuyaud’aér

Página 16 - Notes/ Notas

9 FrInstructions de MontageEXJRPPTuyau de 5,1 ou 7,6 cm (2 ou 3 po) d’aérationdelamaison (non fourni)Tuyau de d´charge de la pompe (non fourni)Clap